Low pressure gas burner

Gas Burners
Low pressure gas burner
<span style="color:white!important"> </span>

SAFETY AND OPERATING INSTRUCTIONS

N ASSEMBLY INSTRUCTIONS 

LGP
Connect the burner stove to the cylinder regulator or to the installation with a flexible hose and 2 clamps or with a threaded flexible hose code 00LI121000. Make sure you use the correct pressure and the hose is within its use-by date. Verify there is no gas leak.

NATURAL GAS
Connect the burner stove to the installation with a threaded flexible hose code 00LI121000. Make sure you use the correct pressure and verify there is no gas leak

N START UP PROCEDURE 
Models without security valve

Open the gas tap turning it counterclockwise and ignite the burner with a flame. Open or close the tap depending on the required power.

Models with security valve

Open the gas tap turning it counterclockwise and ignite the burner with a flame by pressing and holding the safety relieve valve for a few seconds.

Models with security valve and pilot

Ignite the pilot burner with a flame by pressing and holding the safety relieve valve for a few seconds.
Open the gas tap to light the main burner.

Models with piezo igniter

In every case mentioned above: Press the piezo igniter instead of igniting the burner with a flame

N TURN OFF

Turn the gas tap in clockwise direction.
When you close the gas tap in models with a pilot burner, this will remain lighted for future ignitions of the main burner. If you desire to turn the pilot off, you must close the gas tap.

N SAFETY DEVICE (only for models with security valves)

The burner is provided with a thermoelectric safety valve; the thermocouple connected to it shuts the gas off if no flame is to be detected

<hr>
<h3 style="font-weight:bold;color:green;text-align:center;"><!-- [et_pb_line_break_holder] --> TECHNICAL DATA <!-- [et_pb_line_break_holder] --></h3><!-- [et_pb_line_break_holder] --><table><!-- [et_pb_line_break_holder] --><thead><!-- [et_pb_line_break_holder] --><tr><th>MODEL</th> <th>MAX. POWER</th> <th>MAX. CONSUMPTION</th> <th>WORK PRESSURE</th> <th>GAS</th></tr><!-- [et_pb_line_break_holder] --></thead><!-- [et_pb_line_break_holder] --><tbody><!-- [et_pb_line_break_holder] --><tr><td>413 GLP</td> <td>8.000/9.000 Kcal/h</td> <td>745gr/h</td> <td>30/37gr</td> <td>BUT-PROPANE</td></tr><!-- [et_pb_line_break_holder] --><tr><td>413 GN</td> <td>9.500 Kcal/h</td> <td>0,9223Nm3/h</td> <td>22 mbar</td> <td>NATURAL GAS </td></tr><!-- [et_pb_line_break_holder] --><tr><td>416 GLP</td> <td>8.000/9.000 Kcal/h</td> <td>745gr/h</td> <td>30/37gr</td> <td>BUT-PROPANE</td></tr><!-- [et_pb_line_break_holder] --><tr><td>416 GN</td> <td>9.500 Kcal/h</td> <td>0,9223Nm3/h</td> <td>22 mbar</td> <td>NATURAL GAS </td></tr><!-- [et_pb_line_break_holder] --></tbody><!-- [et_pb_line_break_holder] --></table><!-- [et_pb_line_break_holder] -->
<hr>

MAINTENANCE 

Make sure the burner is always clean paying special attention to the fire outlets.
Make sure the security valve and the gas tap are properly working. Verify there is no gas leak.

You can view and download the information on this page in pdf format by clicking on the button

Do you have any doubt?

If you need help do not hesitate to contact us

Contact us through this contact form. If you prefer in the contact section or footer you can find different ways to answer your questions.

Legal warning

13 + 9 =

<script type="text/javascript"><!-- [et_pb_line_break_holder] -->jQuery(function($){<!-- [et_pb_line_break_holder] --> $(".et_pb_contact_field_checkbox label").html("<i></i>Accept<a href='https://gdaparatos.com/en/legal-warning-about-this-page/' target='_blank' style='color:green;'> <strong> Legal warning about this page</strong></a>");<!-- [et_pb_line_break_holder] -->});<!-- [et_pb_line_break_holder] --></script>